SPECIFICATIONS

Construction: Black anodized aluminium

Dimensions:
Right-Angle: 55,6 x 66,8 x 124,5 mm H x W x L
In-Line: 34,3 x 66,8 x 147,3 mm H x W x L
(measured length does not include lens, connectors or cables)

Weight: Approx. 0,29 kg

Environmental Rating: IEC IP20

Operating Temperature: 0° to +50° C

Maximum Relative Humidity: 90%, non-condensing

Display Options: PC and NTSC video (9 m max. cable length)

Imager:
GEO & EDGE: 2,56 x 2,06 mm; 3,25 mm diagonal (1/5" CMOS)
GEO & EDGE 1.3: 8,60 x 6,90 mm; 11,03 mm diagonal (2/3" CMOS)

Acquisition:
GEO & EDGE: Frames per second: 500 max.
GEO & EDGE 1.3: Frames per second: 26,8 max.

Exposure Time:
GEO & EDGE: 0,01 ms to 20,47 ms
GEO & EDGE 1.3: 0,01 ms to 1,67 s

Image Size:
GEO & EDGE: 12.800 (128 x 100) pixels
GEO & EDGE 1.3: 1.310.720 (1280 x 1240) pixels

Pixel Size:
GEO & EDGE: 20 x 20 μm
GEO & EDGE 1.3: 6,7 x 6,7 μm

Levels of Grey Scale: 256

Lens Mount: Standard C-mount

Discrete I/O:
 1 Trigger IN
1 Strobe OUT 5VTTL
4 Programmable I/O
1 Product Change IN
1 Remote TEACH IN

Input Specifications:
NPN: ON <3 V; OFF-State Voltage >10 V at 4 mA max.
PNP: ON >(+V –2) V at 1 mA max.
OFF-State Voltage <3 V at 6 mA max.

Output Configuration:
NPN or PNP software selectable

Output Rating: 150 mA (each)
ON-State Saturation Voltage:
<1 V at 50 mA max. NPN;
<2 V at 50 mA max. PNP

OFF-State Leakage Current: <100 μA NPN or PNP

Communication:
1 RJ-45 10/100 Ethernet port
RS232 flying leads

Memory: Stores up to 12 inspection files (jobs)

Optional: stores up to 150 inspection files (jobs)

Power: Voltage: 10-30V dc

Current:
GEO & EDGE: 500 mA max. (exclusive of load)
GEO & EDGE 1.3: 550 mA max. (exclusive of load)

Supply Protection Circuitry:
Protected against reverse polarity and transient voltages

Bi-Colour Status Indicators:
Green = PASS Green = POWER Green = READY
Red = FAIL Red = ERROR Yellow = TRIGGER