TEKTRON
Home Up Sensors Connectivity Bus Systems Signal Lights Wireless Control Machine Safety Ex-equipment About Us

Contact Us          Quality          Applications          Control Panels          Calibration Service                         email:  sales@tektron.ie               Tel: +353 (0)21 4313331
 

 

Up
Panel Indicators
Field Indicators
Batch Controller
Serial Text Display
Fieldbus Display
Ind Temp Trans
Clock
Set Point Stn
4-20mA Total
Pulse Total
Clock/Timer
Indicating Lamps

 

 

 

 

 

Panel Mounted Digital Indicators - Intrinsically Safe
 

The main application of these instruments is to display a measured variable in meaningful engineering units within a hazardous area. The zero and span of the display are independently adjustable allowing the indicator to be calibrated to display any linear variable represented by the 4/20mA signal. A root extractor and an adjustable sixteen segment lineariser enables the indicator to display flow and non-linear variables such as tank level in linear engineering units. For weighing applications a tare function is included. These digital indicators are often used in an intrinsically safe transmitter loop protected by a Transmitter Barrier. Sometimes the signal originates in the safe area and the signal sent to these displays using a Current Driver Barrier.

Backlight:
A bold digital display provides maximum contrast and has a very wide viewing angle, allowing these indicators to be read easily in most lighting conditions over a wide temperature range. An optional factory fitted backlight is available for applications in poorly illuminated areas. The backlight which may be loop or separately powered is available as a factory fitted option. It provides green background illumination allowing the display to be read at night or in poorly illuminated areas. When powered from the 4/20mA loop no additional intrinsically safe interface or wiring is required and the indicator input remains compliant with the requirements for simple apparatus. Powering from a separate supply produces a brighter backlight but requires an additional intrinsically safe interface and field wiring. Two backlights may be separately powered from one intrinsically safe interface.

Alarms:
Optional dual alarm outputs which can switch hazardous or safe area loads, such as sounders, beacons or solenoid valves, are available as a factory fitted option. The two galvanically isolated solid state alarm outputs may be independently conditioned as high or low alarms with normally open or closed outputs. Annunciators on the display show the status of both alarm outputs.
 

If a suitable mounting enclosure is not readily available, these indicators are available in their own IP66 enclosure, see Field Mounted Indicator models.

Indicators are ATEX certified:

Gas - Group II Category 1G Ex ia IIC T5 Ga -40°C ≤ Ta ≤ +70°C
Dust - Group II Category 1D Ex ia IIIC T80°C Da IP20 -40°C ≤ Ta ≤ +70°C (BA326C Bargraph is not Dust Certified))

IP66 Degree of Production on front (IP65 on BA326C), IP20 at rear. LCD Display and powered by the 4-20mA loop.

Click on Type/Datasheet to access Full Data Sheet

Type/Datasheet Digits Digit Height Front Display Dimensions (mm) Image
BA307E-0 4 15mm  96 x 48
BA308E-0 4 34mm 144 x 72
BA327E-0 5 11mm + Bargraph 96 x 48
BA328E-0 5 29mm 144 x 72
BA326C-0  4.5  +    100 segment bargraph 5.5mm + 95mm Bargraph 148 x 44
ADDITIONAL OPTIONS:

Alarm : Change suffix “-O” in type number to “-A”
Backlight: Change suffix “-O” in type to number “-B”

HOW TO ORDER:

Specify Model Number

Options:    Leave -0 for no options, change to -B for Backlight, Change to -A for Dual Alarms

Specify Display Mode*:    Linear, root or lineariser (intermediate points required)

Specify Calibration:    Reading required at 4.000mA and Reading at 20.000mA
(include decimal point and minus sign if required)

Scale Card:    If Printing Required (Blank is standard, standard units available in pack of 26)

Tag Strip:    If thermally printed tag number is required on rear of instrument

Rear Cover:    Available also as option for BA307 and BA327. (Ask for BA495 rear cover kit)

*  If calibration not specified, display will be set to read linear 0 at 4mA and 100 at 20mA easily recalibrated on site