4/20mA Loop powered indicator, Intrinsically safe, bargraph, panel mounting – BA326C

Features:
Intrinsic safety certification
Combined analogue & digital display
External keypad
Internal calibrator
Square root extractor
Optional:
AlarmsSeparately powered backlight16 point lineariser

4/20mA Loop Powered Indicators, Ex eb and Ex tb, field mounting – BA304SG

Features:
Ex eb and Ex tb certification
Lower cost alternative for flameproof Ex d indicators
May be connected into any Zone 1, 2, 21 or 22 non IS loop
Large non multiplexed displays, models with:
4 digits: 34mm high5 digits: 29mm high + bargraph
IP66 GRP enclosures
-40°C to +60°C operation
Root extractor, lineariser and tare function
Internal calibrator
Optional:
Backlight Scale and tag labelling for no additional chargeEngraved Stainless Steel legend plate

4/20mA Loop Powered Indicators, Ex eb and Ex tb, field mounting – BA324SG

Features:
Ex eb and Ex tb certification
Lower cost alternative for flameproof Ex d indicators
May be connected into any Zone 1, 2, 21 or 22 non IS loop
Large non multiplexed displays, models with:
4 digits: 34mm high5 digits: 29mm high + bargraph
IP66 GRP enclosures
-40°C to +60°C operation
Root extractor, lineariser and tare function
Internal calibrator
Optional:
Backlight Scale and tag labelling for no additional chargeEngraved Stainless Steel legend plate

4/20mA Loop powered indicators, Intrinsically safe, field mounting – BA304G

Features:
Intrinsic safety certification.
Large non multiplexed displays, models with:
4 digits: 34mm high5 digits: 29mm high + bargraph
IP66 GRP or Stainless Steel enclosures
-40°C to +70°C operation
Internal calibrator
Root extractor and lineariser
Tare function
Optional:
Backlight – may be loop or separately poweredAlarmsScale and tag labelling for no additional chargeEngraved Stainless Steel legend plate
Loop powered indicators product summary

4/20mA Loop powered indicators, Intrinsically safe, field mounting – BA304G

Features:
Intrinsic safety certification.
Large non multiplexed displays, models with:
4 digits: 34mm high5 digits: 29mm high + bargraph
IP66 GRP enclosure
-40°C to +70°C operation
Internal calibrator
Root extractor and lineariser
Tare function
Optional:
Backlight – may be loop or separately poweredAlarmsSlide-in escutcheon scale and tag labellingEtched stainless steel legend plate

4/20mA Loop powered indicators, Intrinsically safe, field mounting – BA304G-SS

Features:
Intrinsic safety certification.
Large non multiplexed displays, models with:
4 digits: 34mm high5 digits: 29mm high + bargraph
IP66 GRP or Stainless Steel enclosures
-40°C to +70°C operation
Internal calibrator
Root extractor and lineariser
Tare function
Optional:
Backlight – may be loop or separately poweredAlarmsScale and tag labelling for no additional chargeEngraved Stainless Steel legend plate
Loop powered indicators product summary

4/20mA Loop powered indicators, Intrinsically safe, field mounting – BA324G

Features:
Intrinsic safety certification.
Large non multiplexed displays, models with:
4 digits: 34mm high5 digits: 29mm high + bargraph
IP66 GRP or Stainless Steel enclosures
-40°C to +70°C operation
Internal calibrator
Root extractor and lineariser
Tare function
Optional:
Backlight – may be loop or separately poweredAlarmsScale and tag labelling for no additional chargeEngraved Stainless Steel legend plate
Loop powered indicators product summary

4/20mA Loop powered indicators, Intrinsically safe, field mounting – BA324G

Features:
Intrinsic safety certification.
Large non multiplexed displays, models with:
4 digits: 34mm high5 digits: 29mm high + bargraph
IP66 GRP enclosure
-40°C to +70°C operation
Internal calibrator
Root extractor and lineariser
Tare function
Optional:
Backlight – may be loop or separately poweredAlarmsSlide-in escutcheon scale and tag labellingEtched stainless steel legend plate

4/20mA Loop powered indicators, Intrinsically safe, field mounting – BA324G-SS

Features:
Intrinsic safety certification.
Large non multiplexed displays, models with:
4 digits: 34mm high5 digits: 29mm high + bargraph
IP66 GRP or Stainless Steel enclosures
-40°C to +70°C operation
Internal calibrator
Root extractor and lineariser
Tare function
Optional:
Backlight – may be loop or separately poweredAlarmsScale and tag labelling for no additional chargeEngraved Stainless Steel legend plate
Loop powered indicators product summary

4/20mA Loop powered indicators, Intrinsically safe, panel mounting – BA307E

Features:
Intrinsic safety certification
Large non multiplexed displays, models with:
4 digits: 34mm or 15mm high5 digits: 29mm or 12.7mm high + bargraph
IP66 Front panel
-40°C to +70°C operation
Internal calibrator
Root extractor and lineariser
Tare function
Optional:
Backlight – may be loop or separately poweredAlarms

4/20mA Loop powered indicators, Intrinsically safe, panel mounting – BA308E

Features:
Intrinsic safety certification
Large non multiplexed displays, models with:
4 digits: 34mm or 15mm high5 digits: 29mm or 12.7mm high + bargraph
IP66 Front panel
-40°C to +70°C operation
Internal calibrator
Root extractor and lineariser
Tare function
Optional:
Backlight – may be loop or separately poweredAlarms

4/20mA Loop powered indicators, Intrinsically safe, panel mounting – BA327E

Features:
Intrinsic safety certification
Large non multiplexed displays, models with:
4 digits: 34mm or 15mm high5 digits: 29mm or 12.7mm high + bargraph
IP66 Front panel
-40°C to +70°C operation
Internal calibrator
Root extractor and lineariser
Tare function
Optional:
Backlight – may be loop or separately poweredAlarms

4/20mA Loop powered indicators, Intrinsically safe, panel mounting – BA328E

Features:
Intrinsic safety certification
Large non multiplexed displays, models with:
4 digits: 34mm or 15mm high5 digits: 29mm or 12.7mm high + bargraph
IP66 Front panel
-40°C to +70°C operation
Internal calibrator
Root extractor and lineariser
Tare function
Optional:
Backlight – may be loop or separately poweredAlarms

4/20mA Loop powered rate totaliser, Intrinsically safe, field mounting – BA354E

Features:
Intrinsic safety certification, optional dust
Large easy to read displays:
5 digit 12mm high8 digit 18mm high
IP66 GRP enclosure, separate terminal compartment
Operating temperature -40°C to +70°C
Display functions -20°C to +70°C
Internal calibrator
Root extractor and lineariser
Optional:
External keypadBacklight – may be loop or separately poweredAlarmsEscutcheon scale and tag labellingEtched Stainless Steel legend plate
New application guide

4/20mA Loop powered rate totaliser, Intrinsically safe, panel mounting – BA358E

Features:
Intrinsic safety certification
Large easy to read displays:
5 digit 12mm high8 digit 18mm high
IP66 Front panel
Operating temperature -40°C to +70°C
Display functions -20°C to +70°C
Internal calibrator
Root extractor and lineariser
Optional:
Backlight – may be loop or separately poweredAlarms
New application guide

4/20mA Rugged Loop powered indicators, Intrinsically safe, panel mounting – BA304G-SS-PM

Features:
Intrinsic safety certification
Small models have North American certification
Component certified indicator enclosures permit installation in Ex e, Ex p or Ex t panel enclosure without invalidating the panel enclosure’s certification.
Large non multiplexed displays, models with:
4 digits: 34mm or 15mm high5 digits: 29mm or 12.7mm high + bargraph
IP66 and impact resistant Stainless Steel front panels
-40°C to +70°C operation
Internal calibrator
Root extractor and lineariser
Tare function

4/20mA Rugged Loop powered indicators, Intrinsically safe, panel mounting – BA307E-SS

Features:
Intrinsic safety certification
Small models have North American certification
Component certified indicator enclosures permit installation in Ex e, Ex p or Ex t panel enclosure without invalidating the panel enclosure’s certification.
Large non multiplexed displays, models with:
4 digits: 34mm or 15mm high5 digits: 29mm or 12.7mm high + bargraph
IP66 and impact resistant Stainless Steel front panels
-40°C to +70°C operation
Internal calibrator
Root extractor and lineariser
Tare function
Optional:
Backlight – may be loop or separately poweredAlarms

4/20mA Rugged Loop powered indicators, Intrinsically safe, panel mounting – BA324G-SS-PM

Features:
Intrinsic safety certification
Small models have North American certification
Component certified indicator enclosures permit installation in Ex e, Ex p or Ex t panel enclosure without invalidating the panel enclosure’s certification.
Large non multiplexed displays, models with:
4 digits: 34mm or 15mm high5 digits: 29mm or 12.7mm high + bargraph
IP66 and impact resistant Stainless Steel front panels
-40°C to +70°C operation
Internal calibrator
Root extractor and lineariser
Tare function
Optional:
Backlight – may be loop or separately poweredAlarms

4/20mA Rugged Loop powered indicators, Intrinsically safe, panel mounting – BA327E-SS

Features:
Intrinsic safety certification
Small models have North American certification
Component certified indicator enclosures permit installation in Ex e, Ex p or Ex t panel enclosure without invalidating the panel enclosure’s certification.
Large non multiplexed displays, models with:
4 digits: 34mm or 15mm high5 digits: 29mm or 12.7mm high + bargraph
IP66 and impact resistant Stainless Steel front panels
-40°C to +70°C operation
Internal calibrator
Root extractor and lineariser
Tare function
Optional:
Backlight – may be loop or separately poweredAlarms

8 variable FOUNDATIONâ„¢ fieldbus indicator, Intrinsically safe, field mounting – BA444DF-F

Features:
Intrinsic safety certification.
FISCO compliant
Large 5 digit 20mm high display+ 31 segment bargraph.
Displays up to 8 variables
FOUNDATIONâ„¢ fieldbus protocol
Configurable as Node or Listener
Bus powered
Fieldbus indicators and displays summaryProduct dimensionsFOUNDATIONâ„¢ fieldbus FAQ’S

8 variable FOUNDATIONâ„¢ fieldbus indicator, Intrinsically safe, panel mounting – BA448CF-F

Features:
Intrinsic safety certification
FISCO compliant
Large 5 digit 20mm high display+ 31 segment bargraph.
Displays up to 8 variables
FOUNDATIONâ„¢ fieldbus protocol
Configurable as Node or Listener
Bus powered
Fieldbus indicators and displays summaryProduct dimensionsFOUNDATIONâ„¢ fieldbus FAQ’S

Product details:
Other 8 variable FOUNDATIONâ„¢ fieldbus indicators in our range include:

Intrinsically safe field mounting
General purpose field mounting
General purpose panel mounting

8 Variable PROFIBUS PA indicator, Intrinsically safe, field mounting – BA444DF-P

Features:
Intrinsic safety certification
FISCO compliant
Large 5 digit 20mm high display+ 31 segment bargraph.
Displays up to 8 variables
PROFIBUS PA protocol
Configurable as Node or Listener
Bus powered
Fieldbus indicators and displays summaryProduct dimensionsPROFIBUS PA FAQ’S

8 variable PROFIBUS PA indicator, Intrinsically safe, panel mounting – BA448CF-P

Features:
Intrinsic safety certification.
FISCO compliant
Large 5 digit 20mm high display+ 31 segment bargraph.
Displays up to 8 variables
PROFIBUS PA protocol
Configurable as Node or Listener
Bus powered
Fieldbus indicators and displays summaryProduct dimensionsPROFIBUS PA FAQ’S