Shop
Filter by Output function
- NAMUR 4
Filter by Electrical output
- 1 x 2-pin removable terminal block 4
- 1 x Ex e terminal 4
- 2 x BFOC/2.5 (St) male connector 2
- 2-pin 12
- 4 x 3-pin removable terminal blocks 13
- 4 x 3-pin removable terminal blocks with test socket 5
- 4 x 4 clamps per module 9
- 4 x 5-pin removable terminal blocks 5
- 4 x 5-pin removable terminal blocks with test socket 3
- 4 x BFOC/2.5 (St) male connector 2
- Cable 3
- Connector 1
- Removable screw terminals 4
- Removable spring-type terminals 4
- Removable terminal block 5
- reverse polarity protected 31
- screw connection 9
- screw terminal 26
- spring-type connection 4
- Via module rack 6
Filter by Housing material
Filter by Housing quality
Filter by Operating voltage
- DC 4
Filter by Design
Filter by Measuring principle
Filter by Switching frequency (kHz)
- 0.1 4
Filter by Cable color
- Blue 1
Filter by Connector type
- M12 × 1 1
Filter by Cable length (m)
- 2 3
Filter by Approvals
Filter by Network protocol
Filter by Communication protocol
Showing 121–150 of 188 results
LED Panel lamps, Intrinsically safe – BA390
Features:
Intrinsic safety certification
Red, Amber, Green, Blue and White models
20mA constant current & 4mA low current models
10 year life
IP66 lens
LED Panel lamps, Intrinsically safe – BA390S
Features:
Intrinsic safety certification
Red, Amber, Green, Blue and White models
20mA constant current & 4mA low current models
10 year life
IP66 lens
Modbus RTU display, Intrinsically safe, field mounting – BA484D
Features:
Intrinsic safety certification
High contrast 86.5mm x 45mm display with backlight
Modbus, BEKA & Legacy protocols
Operator push buttons & two solid state outputs
Robust IP66 GRP enclosure
Video: Modbus RTU displays11 Standard displays with up to 8 variablesModbus RTU displays FAQ’S
Product details:
BA201
eleven standard screen formats
ScreenWriter software
Modbus RTU display, Intrinsically safe, panel mounting – BA488C
Features:
Intrinsic safety certification
High contrast 86.5mm x 45mm display with backlight
Modbus, BEKA & Legacy protocols
Operator push buttons & two solid state outputs
Video: Modbus RTU displays11 Standard displays with up to 8 variablesModbus RTU displays FAQ’S
Product details:
BA201
eleven standard screen formats
ScreenWriter software
Pulse input Externally powered rate totalisers, Intrinsically safe, field mounting – BA334E
Features:
Intrinsic safety certification
Proximity detector, open collector, magnetic pick-off, voltage pulse, or switch contact input.
Separate rate and total displays
Lineariser
Isolated synchronous pulse output
Two input model
Optional:
Internally powered display backlightIsolated AlarmsIsolated 4/20mA outputStainless steel legend plate
‘E’ Product dimensions’G’ Product dimensionsNew application guide
Pulse input Externally powered rate totalisers, Intrinsically safe, field mounting – BA334G
Features:
Intrinsic safety certification
Proximity detector, open collector, magnetic pick-off, voltage pulse, or switch contact input.
Separate rate and total displays
Lineariser
Isolated synchronous pulse output
Two input model
Optional:
Internally powered display backlightIsolated AlarmsIsolated 4/20mA outputStainless steel legend plate
‘E’ Product dimensions’G’ Product dimensionsNew application guide
Pulse input Externally powered rate totalisers, Intrinsically safe, field mounting – BA384E
Features:
Intrinsic safety certification
Proximity detector, open collector, magnetic pick-off, voltage pulse, or switch contact input.
Separate rate and total displays
Lineariser
Isolated synchronous pulse output
Two input model
Optional:
Internally powered display backlightIsolated AlarmsIsolated 4/20mA outputStainless steel legend plate
‘E’ Product dimensions’G’ Product dimensionsNew application guide
Pulse input Externally powered rate totalisers, Intrinsically safe, field mounting – BA384G
Features:
Intrinsic safety certification
Proximity detector, open collector, magnetic pick-off, voltage pulse, or switch contact input.
Separate rate and total displays
Lineariser
Isolated synchronous pulse output
Two input model
Optional:
Internally powered display backlightIsolated AlarmsIsolated 4/20mA outputStainless steel legend plate
‘E’ Product dimensions’G’ Product dimensionsNew application guide
Pulse input Externally powered rate totalisers, Intrinsically safe, panel mounting – BA337E
Features:
Intrinsic safety certification
Proximity detector, magnetic pick-off, voltage pulse, or switch contact input.
Separate rate and total displays
Lineariser
Two input model
Rugged Stainless Steel model for use in Ex e, Ex n, Ex p and in Ex t panel enclosures in Zones 1, 2, 21 & 22.
BA338E has isolated synchronous pulse output as standard
Optional:
Internally powered display backlightIsolated AlarmsIsolated 4/20mA outputBA337E and BA337E-SS isolated synchronous pulse output
96 x 48mm Product dimensions105 x 60mm Product dimensions144 x 72mm Product dimensionsNew application guide
Pulse input Externally powered rate totalisers, Intrinsically safe, panel mounting – BA337E-SS
Features:
Intrinsic safety certification
Proximity detector, magnetic pick-off, voltage pulse, or switch contact input.
Separate rate and total displays
Lineariser
Two input model
Rugged Stainless Steel model for use in Ex e, Ex n, Ex p and in Ex t panel enclosures in Zones 1, 2, 21 & 22.
BA338E has isolated synchronous pulse output as standard
Optional:
Internally powered display backlightIsolated AlarmsIsolated 4/20mA outputBA337E and BA337E-SS isolated synchronous pulse output
96 x 48mm Product dimensions105 x 60mm Product dimensions144 x 72mm Product dimensionsNew application guide
Pulse input Externally powered rate totalisers, Intrinsically safe, panel mounting – BA338E
Features:
Intrinsic safety certification
Proximity detector, magnetic pick-off, voltage pulse, or switch contact input.
Separate rate and total displays
Lineariser
Two input model
Rugged Stainless Steel model for use in Ex e, Ex n, Ex p and in Ex t panel enclosures in Zones 1, 2, 21 & 22.
BA338E has isolated synchronous pulse output as standard
Optional:
Internally powered display backlightIsolated AlarmsIsolated 4/20mA outputBA337E and BA337E-SS isolated synchronous pulse output
96 x 48mm Product dimensions105 x 60mm Product dimensions144 x 72mm Product dimensionsNew application guide
Pulse input Externally powered rate totalisers, Intrinsically safe, panel mounting – BA388E
Features:
Intrinsic safety certification
Proximity detector, magnetic pick-off, voltage pulse, or switch contact input.
Separate rate and total displays
Lineariser
Two input model
Rugged Stainless Steel model for use in Ex e, Ex n, Ex p and in Ex t panel enclosures in Zones 1, 2, 21 & 22.
BA338E has isolated synchronous pulse output as standard
Optional:
Internally powered display backlightIsolated AlarmsIsolated 4/20mA outputBA337E and BA337E-SS isolated synchronous pulse output
96 x 48mm Product dimensions105 x 60mm Product dimensions144 x 72mm Product dimensionsNew application guide
Rugged 4/20mA Loop powered indicators, Ex ec and Ex tc, panel mounting – BA307SE
Features:
Ex ec & Ex tc certification eliminates the need for Zener barriers and galvanic isolators.
Large non multiplexed displays, models with:
4 digits: 15mm high5 digits: 12.7mm high + bargraph
Rugged Stainless Steel cases for use in Ex e, Ex p and Ex t panel enclosures in Zones 2 & 22.
Internal calibrator
Root extractor and lineariser
Tare function
Optional:
Backlight – may be loop or separately poweredAlarm output terminals