Shop
Filter by Output function
- NAMUR 4
Filter by Electrical output
- 1 x 2-pin removable terminal block 4
- 1 x Ex e terminal 4
- 2 x BFOC/2.5 (St) male connector 2
- 2-pin 12
- 4 x 3-pin removable terminal blocks 13
- 4 x 3-pin removable terminal blocks with test socket 5
- 4 x 4 clamps per module 9
- 4 x 5-pin removable terminal blocks 5
- 4 x 5-pin removable terminal blocks with test socket 3
- 4 x BFOC/2.5 (St) male connector 2
- Cable 3
- Connector 1
- Removable screw terminals 4
- Removable spring-type terminals 4
- Removable terminal block 5
- reverse polarity protected 31
- screw connection 9
- screw terminal 26
- spring-type connection 4
- Via module rack 6
Filter by Housing material
Filter by Housing quality
Filter by Operating voltage
- DC 4
Filter by Design
Filter by Measuring principle
Filter by Switching frequency (kHz)
- 0.1 4
Filter by Cable color
- Blue 1
Filter by Connector type
- M12 × 1 1
Filter by Cable length (m)
- 2 3
Filter by Approvals
Filter by Network protocol
Filter by Communication protocol
Showing 31–60 of 188 results
BA212 Pageant Power Isolator IIA & IIB Applications – BA212
Features:
Galvanic Power Isolator – single channel
Intrinsic safety Ex ia associated apparatus certification.
High power
Uo = 12.4V; Io = 2.66A; Po = 5.2W
Increased safety Ex ec certification for installation in Zone 2
BA243 Pageant Power Isolator IIC Applications – BA243
Features:
Galvanic Power Isolator – four channels
Intrinsic safety Ex ia associated apparatus certification.
High power – combined Po 5.2W
Uo = 12.4V; Io = 0.67A; Po = 1.36W for each channel
Increased safety Ex ec certification for installation in Zone 2
Primarily intended for powering a Pageant Operator Panel in Group IIC atmosphere
BA3101 and BA3102 Pageant Operator Displays – BA3101
Features:
Economical solution for Zone 1 applications
7 inch Backlit operator screen
8 touch buttons with tricolour annunciators
Accommodates:
Plug-in CPU module containing embedded CODESYS® PLC software and optional RS485-IS port.Up to 7 plug-in input and output modules.
IP66 stainless steel front panel with:
BA3101 Toughened glass display windowBA3102 Impact resistant display window certified for installation in Ex e or Ex t enclosure.
Pageant product summaryPageant explainedPageant Codesys Quick Start Guide
BA3101 and BA3102 Pageant Operator Displays – BA3102
Features:
Economical solution for Zone 1 applications
7 inch Backlit operator screen
8 touch buttons with tricolour annunciators
Accommodates:
Plug-in CPU module containing embedded CODESYS® PLC software and optional RS485-IS port.Up to 7 plug-in input and output modules.
IP66 stainless steel front panel with:
BA3101 Toughened glass display windowBA3102 Impact resistant display window certified for installation in Ex e or Ex t enclosure.
Pageant product summaryPageant explainedPageant Codesys Quick Start Guide
BA3201 Pageant CPU Module – BA3201
Features:
Ex ia intrinsic safety certification
Certification allows module to be plugged into a Pageant BA3101 Ex ia intrinsically safe Operator Display.
Module contains:
Power connectionCentral ProcessorCODESYS® runtime software and application codeIEC 61131-3 compliant PLCVisualization engine
Programming port enables CODESYS application code to be downloaded in a safe area.
BA3202 Pageant CPU Module with Modbus RTU Communication – BA3202
Features:
Ex ia intrinsic safety certification
Certification allows module to be plugged into a Pageant BA3101 Ex ia intrinsically safe Operator Display.
Module contains:
Power connectionCentral ProcessorCODESYS® runtime software and application codeIEC 61131-3 compliant PLCVisualization engineModbus RTU
Isolated RS485-IS communication port
Programming port enables CODESYS application code to be downloaded in a safe area.
BA329-GL and BA329-PC Eight input 4/20mA externally powered indicators – BA329-GL
Features:
No programming required
Easy configuration and calibration via front panel touch buttons.
8 touch buttons with tricolour annunciators
Ex ia intrinsic safety certification
Space saving for Zone 1, 2, 21 and 22 applications
8 galvanically isolated 4/20mA inputs
7 inch backlit screen
IP66 stainless steel front panel with:
BA329-GLÂ Â Toughened glass display windowBA329-PCÂ Â Impact resistant display window certified for installation in Ex e or Ex t enclosure.
Also see extensive range of loop powered 4/20mA indicators
BA329-GL and BA329-PC Eight input 4/20mA externally powered indicators – BA329-PC
Features:
No programming required
Easy configuration and calibration via front panel touch buttons.
8 touch buttons with tricolour annunciators
Ex ia intrinsic safety certification
Space saving for Zone 1, 2, 21 and 22 applications
8 galvanically isolated 4/20mA inputs
7 inch backlit screen
IP66 stainless steel front panel with:
BA329-GLÂ Â Toughened glass display windowBA329-PCÂ Â Impact resistant display window certified for installation in Ex e or Ex t enclosure.
Also see extensive range of loop powered 4/20mA indicators
BA3301 Pageant Analogue Input Module 4 x 4/20mA – BA3301
Features:
Four 4/20mA unpowered inputs
Each input is galvanically isolated
Ex ia intrinsic safety certification
Certification allows module to be plugged into a Pageant BA3101 Ex ia intrinsically safe Operator Display
BA3401 Pageant Digital Input Module 8 x Contact – BA3401
Features:
Eight contact or open collector inputs
Each input is a separate intrinsically safe circuit
Ex ia intrinsic safety certification
Certification allows module to be plugged into a Pageant BA3101 Ex ia intrinsically safe Operator Display
BA3402 Pageant Digital Input Module 8 x Proximity Detector – BA3402
Features:
Eight NAMUR 2-wire proximity detector inputs
Two inputs can decode a quadrature signal
Each input is a separate intrinsically safe circuit
Ex ia intrinsic safety certification
Certification allows module to be plugged into a Pageant BA3101 Ex ia intrinsically safe Operator Display
BA3501 Pageant Analogue Output Module 4 x 4/20mA – BA3501
Features:
Four 4/20mA unpowered outputs
Each output is galvanically isolated
Ex ia intrinsic safety certification
Certification allows module to be plugged into a Pageant BA3101 Ex ia intrinsically safe Operator Display
BA3601 Pageant Digital Output Module 4 x Contact – BA3601
Features:
Four contact outputs
Each output is galvanically isolated
Ex ia intrinsic safety certification
Certification allows module to be plugged into a Pageant BA3101 Ex ia intrinsically safe Operator Display
BA3701 Pageant Digital Input Module 2 x Totaliser or Counter – BA3701
Features:
Two counter channels each configurable for NAMUR proximity detector, open collector, switch contact or a voltage pulse input.
Each channel is a separate intrinsically safe circuit
Galvanically isolated synchronous pulse output from each channel for retransmission application.
Ex ia intrinsic safety certification
Certification allows module to be plugged into a Pageant BA3101 Ex ia intrinsically safe Operator Display
BA3901 Pageant Power Combiner – BA3901
Features:
Remotely combines four separate intrinsically safe power supplies.
Mounts onto the rear of a plug-in CPU module including BA3201 and BA3202.
In IIC hydrogen atmospheres, enables a longer cable to be used between a BA3101 Operator Display and BA243 Power Isolator in a safe area or Zone 2.
Ex ia intrinsic safety certification
Communications isolator – BA201
Features:
Intrinsic safety associated apparatus certification.
Powers and communicates with BA484D & BA488C serial text [data] displays.
RS232 and RS485 safe area port
35mm DIN rail mounting
Video: Modbus RTU displays
Counters, Intrinsically safe, field mounting – BA364E
Features:
Intrinsic safety certification
Proximity detector, open collector, magnetic pick-off, voltage pulse, or switch contact input.
Separate total and rate displays
Counters can display the sum or differences of the two inputs and includes a quadrature decoder for position measurements.
Isolated synchronous pulse output
Optional:
Internally powered display backlightIsolated AlarmsIsolated 4/20mA outputStainless steel legend plate
‘E’ Product dimensions’G’ Product dimensionsNew application guide
Counters, Intrinsically safe, field mounting – BA364G
Features:
Intrinsic safety certification
Proximity detector, open collector, magnetic pick-off, voltage pulse, or switch contact input.
Separate total and rate displays
Counters can display the sum or differences of the two inputs and includes a quadrature decoder for position measurements.
Isolated synchronous pulse output
Optional:
Internally powered display backlightIsolated AlarmsIsolated 4/20mA outputStainless steel legend plate
‘E’ Product dimensions’G’ Product dimensionsNew application guide
Counters, Intrinsically safe, panel mounting – BA367E
Features:
Intrinsic safety certification
Proximity detector, magnetic pick-off, voltage pulse, or switch contact input.
Separate total and rate displays
Two input model can display sum or differences of inputs and includes quadrature decoder for position measurements.
Rugged Stainless Steel model for use in Ex e, Ex n, Ex p and in Ex t panel enclosures in Zones 1, 2, 21 & 22.
BA368E has isolated synchronous pulse output as standard
Optional:
Internally powered display backlightIsolated AlarmsIsolated 4/20mA outputBA367E and BA367E-SS isolated synchronous pulse output
96 x 48mm Product dimensions105 x 60mm Product dimensions (Rugged SS)144 x 72mm Product dimensionsNew application guide
Counters, Intrinsically safe, panel mounting – BA367E-SS
Features:
Intrinsic safety certification
Proximity detector, magnetic pick-off, voltage pulse, or switch contact input.
Separate total and rate displays
Two input model can display sum or differences of inputs and includes quadrature decoder for position measurements.
Rugged Stainless Steel model for use in Ex e, Ex n, Ex p and in Ex t panel enclosures in Zones 1, 2, 21 & 22.
BA368E has isolated synchronous pulse output as standard
Optional:
Internally powered display backlightIsolated AlarmsIsolated 4/20mA outputBA367E and BA367E-SS isolated synchronous pulse output
96 x 48mm Product dimensions105 x 60mm Product dimensions (Rugged SS)144 x 72mm Product dimensionsNew application guide
Counters, Intrinsically safe, panel mounting – BA368E
Features:
Intrinsic safety certification
Proximity detector, magnetic pick-off, voltage pulse, or switch contact input.
Separate total and rate displays
Two input model can display sum or differences of inputs and includes quadrature decoder for position measurements.
Rugged Stainless Steel model for use in Ex e, Ex n, Ex p and in Ex t panel enclosures in Zones 1, 2, 21 & 22.
BA368E has isolated synchronous pulse output as standard
Optional:
Internally powered display backlightIsolated AlarmsIsolated 4/20mA outputBA367E and BA367E-SS isolated synchronous pulse output
96 x 48mm Product dimensions105 x 60mm Product dimensions (Rugged SS)144 x 72mm Product dimensionsNew application guide
Eight variable FOUNDATIONâ„¢ fieldbus display, Intrinsically safe, field mounting – BA484DF-F
Features:
Intrinsic safety certification
FISCO compliant
High contrast 86.5mm x 45mm display with backlight
Up to 8 fieldbus variables
Internal calibrator
FOUNDATIONâ„¢ fieldbus protocol
ITK 6.3 compliant
Bus powered
Six optional alarm outputs
Standard displaysFOUNDATIONâ„¢ fieldbus FAQ’S
Eight variable FOUNDATIONâ„¢ fieldbus display, Intrinsically safe, panel mounting – BA488CF-F
Features:
Intrinsic safety certification
FISCO compliant
High contrast 86.5mm x 45mm display with backlight
Up to 8 fieldbus variables
FOUNDATIONâ„¢ fieldbus protocol
ITK 6.3 compliant
Bus powered
Six optional alarm outputs
Standard displaysFOUNDATIONâ„¢ fieldbus FAQ’S
Eight variable PROFIBUS PA display, Intrinsically safe, field mounting – BA484DF-P
Features:
Intrinsic safety certification
FISCO compliant
High contrast 86.5mm x 45mm display with backlight
Up to 8 fieldbus variables
PROFIBUS PA protocol
Bus powered
Six optional alarm outputs
Push buttons may be used to send operator commands to the fieldbus host.
Standard displaysPROFIBUS PA FAQ’S
Eight variable PROFIBUS PA display, Intrinsically safe, panel mounting – BA488CF-P
Features:
Intrinsic safety certification
FISCO compliant
High contrast 86.5mm x 45mm display with backlight
Up to 8 fieldbus variables
PROFIBUS PA protocol
Bus powered
Six optional alarm outputs
Push buttons may be used to send operator commands to the fieldbus host.
Standard displaysPROFIBUS PA FAQ’S