Shop
Filter by Output function
- NAMUR 4
Filter by Electrical output
- 1 x 2-pin removable terminal block 4
- 1 x Ex e terminal 4
- 2 x BFOC/2.5 (St) male connector 2
- 2-pin 12
- 4 x 3-pin removable terminal blocks 13
- 4 x 3-pin removable terminal blocks with test socket 5
- 4 x 4 clamps per module 9
- 4 x 5-pin removable terminal blocks 5
- 4 x 5-pin removable terminal blocks with test socket 3
- 4 x BFOC/2.5 (St) male connector 2
- Cable 3
- Connector 1
- Removable screw terminals 4
- Removable spring-type terminals 4
- Removable terminal block 5
- reverse polarity protected 31
- screw connection 9
- screw terminal 26
- spring-type connection 4
- Via module rack 6
Filter by Housing material
Filter by Housing quality
Filter by Operating voltage
- DC 4
Filter by Design
Filter by Measuring principle
Filter by Switching frequency (kHz)
- 0.1 4
Filter by Cable color
- Blue 1
Filter by Connector type
- M12 × 1 1
Filter by Cable length (m)
- 2 3
Filter by Approvals
Filter by Network protocol
Filter by Communication protocol
Showing 151–180 of 188 results
Rugged 4/20mA Loop powered indicators, Ex ec and Ex tc, panel mounting – BA327SE
Features:
Ex ec & Ex tc certification eliminates the need for Zener barriers and galvanic isolators.
Large non multiplexed displays, models with:
4 digits: 15mm high5 digits: 12.7mm high + bargraph
Rugged Stainless Steel cases for use in Ex e, Ex p and Ex t panel enclosures in Zones 2 & 22.
Internal calibrator
Root extractor and lineariser
Tare function
Optional:
Backlight – may be loop or separately poweredAlarm output terminals
Rugged Set point station [set point generator], Intrinsically safe, panel mounting – BA427E-SS
Features:
Ex ia intrisic safety certification
Rugged stainless steel model that may be mounted in an Ex e, Ex p, Ex n or Ex t panel enclosures without invalidating panel enclosure certification.
Panel mounting IP66 front
Loop powered
Front panel push buttons
5 digit display with bargraph
Optional:
Backlight – may be loop or separately poweredBA490 Rotary encoder
Rugged Stainless Steel 4/20mA Loop powered indicators, field mounting – BA304G-SS
Features:
Intrinsically safe and general purpose models.
Large non multiplexed displays, models with:
4 digits: 34mm high5 digits: 29mm high + bargraph
-40°C to +70°C operation
Internal calibrator
Root extractor and lineariser
Optional:
Backlight – may be loop or separately poweredAlarmsScale and tag labelling for no additional chargeEngraved Stainless Steel legend plate
Rugged Stainless Steel 4/20mA Loop powered indicators, field mounting – BA324G-SS
Features:
Intrinsically safe and general purpose models.
Large non multiplexed displays, models with:
4 digits: 34mm high5 digits: 29mm high + bargraph
-40°C to +70°C operation
Internal calibrator
Root extractor and lineariser
Optional:
Backlight – may be loop or separately poweredAlarmsScale and tag labelling for no additional chargeEngraved Stainless Steel legend plate
Rugged Stainless Steel 4/20mA Loop powered indicators, panel mounting – BA304G-SS-PM
Features:
Intrinsically safe and general purpose models
Component certified indicator enclosures permit installation in Ex e, Ex p or Ex t panel enclosure without invalidating the panel enclosure’s certification
Large non multiplexed displays, models with:
4 digits: 34mm or 15mm high5 digits: 29mm or 11mm high + bargraph
IP66 and impact resistant stainless steel front panels
-40°C to +70°C operation
Internal calibrator
Root extractor and lineariser
Tare function
Optional:
Backlight – may be loop or separately poweredAlarms
Display optionsProduct dimensionsRugged indicators product summaryApplication guide AG300
Rugged Stainless Steel 4/20mA Loop powered indicators, panel mounting – BA324G-SS-PM
Features:
Intrinsically safe and general purpose models
Component certified indicator enclosures permit installation in Ex e, Ex p or Ex t panel enclosure without invalidating the panel enclosure’s certification
Large non multiplexed displays, models with:
4 digits: 34mm or 15mm high5 digits: 29mm or 11mm high + bargraph
IP66 and impact resistant stainless steel front panels
-40°C to +70°C operation
Internal calibrator
Root extractor and lineariser
Tare function
Optional:
Backlight – may be loop or separately poweredAlarms
Display optionsProduct dimensionsRugged indicators product summaryApplication guide AG300
Serial Data display, Intrinsically safe, field mounting – BA484D
Features:
Intrinsic safety certification
High contrast 86.5mm x 45mm display with backlight
Modbus, BEKA & Legacy protocols
Operator push buttons & two solid state outputs
Robust IP66 GRP enclosure
11 Standard displays with up to 8 variablesSerial Data displays FAQ’S
Product details:
BA201
eleven standard screen formats
ScreenWriter software
Serial Data display, Intrinsically safe, panel mounting – BA488C
Features:
Intrinsic safety certification
High contrast 86.5mm x 45mm display with backlight
Modbus, BEKA & Legacy protocols
Operator push buttons & two solid state outputs
11 Standard displays with up to 8 variablesSerial Data displays FAQ’S
Product details:
BA201
eleven standard screen formats
ScreenWriter software
Set point stations [set point generator], Intrinsically safe, panel mounting – BA427E
Features:
Intrisic safety certification
Loop powered
Front panel push buttons
5 digit display with bargraph
IP66 Front panel
Rugged Stainless Steel model for use in Ex e, Ex n, Ex p and Ex t panel enclosures in Zones 1, 2, 21 & 22.
Panel mounting
Optional:
Backlight – may be loop or separately poweredBA490 Rotary encoder
96 x 48mm Product dimensions105 x 60mm Product dimensions (Rugged SS)
Set point stations [set point generator], Intrinsically safe, panel mounting – BA427E-SS
Features:
Intrisic safety certification
Loop powered
Front panel push buttons
5 digit display with bargraph
IP66 Front panel
Rugged Stainless Steel model for use in Ex e, Ex n, Ex p and Ex t panel enclosures in Zones 1, 2, 21 & 22.
Panel mounting
Optional:
Backlight – may be loop or separately poweredBA490 Rotary encoder
96 x 48mm Product dimensions105 x 60mm Product dimensions (Rugged SS)
Single variable FOUNDATIONâ„¢ fieldbus indicator, Intrinsically safe, field mounting – BA414DF-F
Features:
Intrinsic safety certification
FISCO compliant
Large 5 digit 20mm high display+ 31 segment bargraph.
Displays single fieldbus variable
FOUNDATIONâ„¢ fieldbus protocol
ITK 6.3 compliant
Bus powered
Single variable FOUNDATION™ fieldbus indicator, Intrinsically safe, panel mounting – BA418CF-F
Features:
Intrinsic safety certification
FISCO compliant
Large 5 digit 20mm high display+ 31 segment bargraph.
Displays single fieldbus variable
FOUNDATIONâ„¢ fieldbus protocol
ITK 6.3 compliant
Bus powered
Sounders and Beacons, Flameproof / explosion proof – BExBG05D
Features:
Flameproof certification
3 stage sounders with 32 different tones
6 beacon colours
Listen to our BR385 sounder tone samples
Sounders and Beacons, Flameproof / explosion proof – BExCS110-05D
Features:
Flameproof certification
3 stage sounders with 32 different tones
6 beacon colours
Listen to our BR385 sounder tone samples
Sounders and Beacons, Flameproof / explosion proof – BExS110D
Features:
Flameproof certification
3 stage sounders with 32 different tones
6 beacon colours
Listen to our BR385 sounder tone samples
Sounders and Beacons, Intrinsically safe – BA386
Features:
Intrinsic safety certification
3 stage sounder with 49 different tones
Red, Amber, Green, Blue, & White flashing and steady state beacon.
Sounder & flashing beacon may be used together with ‘alarm accept’ function.
Listen to our BR385 sounder tone samples
Sounders and Beacons, Intrinsically safe – BA386S
Features:
Intrinsic safety certification
3 stage sounder with 49 different tones
Red, Amber, Green, Blue, & White flashing and steady state beacon.
Sounder & flashing beacon may be used together with ‘alarm accept’ function.
Listen to our BR385 sounder tone samples
Sounders and Beacons, Intrinsically safe – BR385
Features:
Intrinsic safety certification
3 stage sounder with 49 different tones
Red, Amber, Green, Blue, & White flashing and steady state beacon.
Sounder & flashing beacon may be used together with ‘alarm accept’ function.
Listen to our BR385 sounder tone samples
Tachometers, Intrinsically safe, field mounting – BA314E
Features:
Intrinsic safety certification
Proximity detector, open collector, magnetic pick-off, voltage pulse, or switch contact input.
Separate speed and run-time displays
Isolated synchronous pulse output
Optional:
Internally powered display backlightIsolated AlarmsIsolated 4/20mA outputStainless steel legend plate
‘E’ Product dimensions’G’ Product dimensionsNew application guide
Tachometers, Intrinsically safe, field mounting – BA314G
Features:
Intrinsic safety certification
Proximity detector, open collector, magnetic pick-off, voltage pulse, or switch contact input.
Separate speed and run-time displays
Isolated synchronous pulse output
Optional:
Internally powered display backlightIsolated AlarmsIsolated 4/20mA outputStainless steel legend plate
‘E’ Product dimensions’G’ Product dimensionsNew application guide
Tachometers, Intrinsically safe, panel mounting – BA317E
Features:
Intrinsic safety certification
Proximity detector, magnetic pick-off, voltage pulse, or switch contact input.
Separate speed and run-time displays
Rugged Stainless Steel model for use in Ex e, Ex n, Ex p and Ex t panel enclosures in Zones 1, 2, 21 & 22.
BA318E has isolated synchronous pulse output as standard
Optional:
Internally powered display backlightIsolated AlarmsIsolated 4/20mA outputBA317E and BA317E-SS isolated synchronous pulse output.
96 x 48mm Product dimensions105 x 60mm Product dimensions144 x 72mm Product dimensionsNew application guide
Tachometers, Intrinsically safe, panel mounting – BA317E-SS
Features:
Intrinsic safety certification
Proximity detector, magnetic pick-off, voltage pulse, or switch contact input.
Separate speed and run-time displays
Rugged Stainless Steel model for use in Ex e, Ex n, Ex p and Ex t panel enclosures in Zones 1, 2, 21 & 22.
BA318E has isolated synchronous pulse output as standard
Optional:
Internally powered display backlightIsolated AlarmsIsolated 4/20mA outputBA317E and BA317E-SS isolated synchronous pulse output.
96 x 48mm Product dimensions105 x 60mm Product dimensions144 x 72mm Product dimensionsNew application guide
Tachometers, Intrinsically safe, panel mounting – BA318E
Features:
Intrinsic safety certification
Proximity detector, magnetic pick-off, voltage pulse, or switch contact input.
Separate speed and run-time displays
Rugged Stainless Steel model for use in Ex e, Ex n, Ex p and Ex t panel enclosures in Zones 1, 2, 21 & 22.
BA318E has isolated synchronous pulse output as standard
Optional:
Internally powered display backlightIsolated AlarmsIsolated 4/20mA outputBA317E and BA317E-SS isolated synchronous pulse output.
96 x 48mm Product dimensions105 x 60mm Product dimensions144 x 72mm Product dimensionsNew application guide